Time Delay Class RK5 fuses are designed to provide protection in electrical systems where moderate overload and short-circuit currents occur. These fuses find application in industrial machinery, motor control centers, power distribution panels, commercial buildings, control panels, and various electrical systems where protection against overcurrent and short-circuit events is required.
Features of FRS-R Series Fuses
1. Dual Element: The term "Dual element" refers to the construction of the fuse. These fuses have two separate current-carrying elements. One element is designed to handle the normal operating current of the circuit, while the other element is intended to handle short-circuit currents. This dual element design provides additional protection against high fault currents. Dual element also provides excellent time delay performance, enabling precise sizing and superior protection for motors and transformers.
2. Rated Voltage: The fuse is rated for a maximum voltage of 690VAC (alternating current) and 300VDC (direct current). This means it is suitable for use in electrical systems operating at or below these voltage levels.
3. Time Delay (T): Class RK5 fuses are designed with a time delay characteristic, which means they can tolerate temporary overloads without blowing immediately. The time delay feature allows the fuse to withstand short-duration current surges, such as motor starting currents or inrush currents during equipment operation. And time-delay feature also allows the use of smaller fuse amp ratings, resulting in cost savings by enabling the use of smaller switches, panels, and fuses themselves.
4. High breaking capacity: These fuses provide a 10-second time delay at 5 times the rated current. Class RK5 fuses with a 200 kA interrupting rating can be applied in a wide range of applications.
Product name: | Time Delay Class RK5 Fuses | Size: | 20.4 mm x 76.5 mm / 0.81 x 3 inches |
Rated Voltage: |
690Vac, 300Vdc | Rated Current: | 10A To 30A |
Interrupting rating: | 200 kA Vac RMS Sym / 20 kA Vdc | Time-delay: | 10 second (minimum) at 500% of rated current |
Type: | Time-delay | Standard: | UL/CSA/CE |
600 vac 300 vds 30A Time Delay Class RK5 Fuses can find applications in various electrical systems. Some common applications include:
1. Industrial Motor Starters: Motor starters are commonly used in various industrial applications to control the operation of electric motors. Fuses with the described specifications may be used within motor starters to provide protection against overcurrents and short circuits.
2. HVAC Systems: Heating, ventilation, and air conditioning (HVAC) systems in commercial buildings often incorporate electrical components that require circuit protection. Fuses with similar specifications can be utilized to protect the electrical circuits and equipment within HVAC systems.
3. Control Panels and PLCs: Control panels and programmable logic controllers (PLCs) are used in industrial automation and process control applications. Fuses with the described specifications might be employed in these systems to protect control circuits and equipment from overcurrent events.
4. Power Distribution Units (PDUs): PDUs are used to distribute electrical power within data centers, server rooms, and other IT environments. Fuses with similar specifications can be used in PDUs to protect power distribution circuits and equipment.
5. Electrical Panels and Switchgear: Electrical panels and switchgear are found in various applications, including commercial buildings, industrial facilities, and power distribution systems. Fuses with the described specifications may be used within these panels and switchgear to provide protection for the connected circuits.